Platform · Sensor Hub

What Is a Sensor Hub? How One Module Lets a Data Center See Heat, Hear Faults and Smell Trouble

Updated · FacilityOps researchers and writers

Last updated · By FacilityOps

Quick answer: A FacilityOps sensor hub is a proprietary, plug and play module that can be fitted with whatever sensors a job needs. It can ride on a robot or a drone, or be fixed in place as a stationary unit, and everything it measures feeds the same FacilityOps platform. Think of it as a set of senses that can be moved to wherever a facility needs eyes, ears and a nose.

Key takeaways

  • A sensor hub separates the senses from the machine that carries them. The same hub can ride on a robot, fly on a drone or sit fixed in one room.
  • Different failures give off different signals: heat, vibration, ultrasound, gas, moisture, dust. A hub carries several sensors so it can catch each one.
  • Every reading is tied to a specific asset, a position and a time, so it becomes evidence rather than a loose number.
  • Stationary hubs watch small rooms and high risk spots around the clock. Robots cover the whole facility. A hub alert can send a robot to investigate.
  • After a repair, a hub can watch the fixed spot for a set period to prove the fix held.
  • The whole stack is customizable. Each site gets the sensors its rooms and risks actually need.

A data center is full of machines that warn you before they fail.

A loose electrical connection gets warm. A worn fan bearing starts to shake. A stressed battery lets off gas. A leaking pipe leaves water where water should never be.

The problem is that each warning speaks a different language. Heat is invisible to the eye. Ultrasound is too high pitched for the ear. No single instrument hears all of them.

A sensor hub solves that by putting many senses into one module, and letting you choose where that module goes. This guide covers what a hub is, what every sensor in it measures, the real incidents that show why each one matters, and how hubs on robots, drones and walls work together.


What is a sensor hub?

Short answer: a sensor hub is a single module that holds many sensors, ties every reading to the right asset, and sends it all to one platform. What carries it is a choice.

Picture a skilled inspector walking a data center. Their eyes spot a propped door. Their hand feels a warm panel. Their ears notice a fan that sounds wrong. Their nose catches a strange smell near the batteries.

Now split that inspector into two parts: the senses and the legs.

The sensor hub is the senses. The robot, the drone or the wall mount is the legs. Because the two are separate, you can put the same senses wherever they are most useful:

  • On an autonomous mobile robot that walks the data halls and visits hundreds of assets on a route
  • On a drone that reaches high and overhead places
  • Fixed in one spot, keeping watch around the clock

Three words describe the FacilityOps hub:

  • Proprietary: FacilityOps designs it, and the intelligence that makes sense of the readings lives in the hub and the platform.
  • Plug and play: add a sensor to the hub and it works without rebuilding the machine underneath.
  • Customizable: each hub carries only the sensors its job needs, so a battery closet and a data hall can have very different hubs.

Because the intelligence lives in the hub and the platform, not in one specific machine, FacilityOps is hardware agnostic. The same senses can ride on different robot platforms.


Why does a data center need more than one kind of sensor?

Short answer: because a failure gives off different signals at different stages, and each sensor catches a different stage.

Take a cooling fan with a bearing that is starting to wear out. It does not fail all at once. It moves through stages, and each stage gives off a different signal:

  1. First, the shaking changes. The worn bearing adds a new, faster rhythm to the fan's normal vibration. A vibration sensor picks this up while the fan still seems fine.
  2. Next, it makes ultrasound. Metal rubbing on metal creates high pitched sound above human hearing. An ultrasonic sensor hears it.
  3. Then it gets loud. The noise drops into the range people can hear. A microphone hears it, but people nearby often stop noticing.
  4. Then it gets hot. Friction turns into heat. A thermal camera sees it.
  5. Finally, smoke. If nothing is done, overheating can lead to smoke, which can trip fire alarms and suppression systems.

The earlier you catch it, the more time you have to plan a calm repair. A thermal camera alone would only see stage four.

That is why one sensor is never enough. When two different sensors agree, such as a hot spot plus an ultrasonic crackle at the same breaker, the evidence is far stronger than either reading alone.


What does each sensor in the hub measure, and what does it catch?

Short answer: each sensor measures one physical signal, such as light, heat, motion, sound, gas, water or distance, and each signal reveals a different kind of problem.

Below is every part of the FacilityOps sensor stack, grouped by the sense it gives the facility. The core payload in data centers today covers cameras and gauge reading, thermal imaging, vibration, acoustic and ultrasonic sensing, climate sensing, particulate sensing, VOC and gas sensing, and smoke sensing. The rest of the stack is fitted per site, wherever a room or risk calls for it.

For each one you will find what it measures, what it catches, and a real incident that shows why it matters.

Cameras and gauge reading: the sense of sight

What it measures: visible light, captured as color images, the foundation of every visual inspection. A pan tilt zoom camera can aim and magnify, so one camera can read a small label from across an aisle. A 360 degree camera captures a whole room in one frame.

Software then reads what the camera sees. Optical character recognition (OCR) turns a picture of text or numbers into actual text, and vision software reads dial needles, indicator lights and valve handles.

What it catches: propped fire doors, blocked exits and vents, boxes in equipment spaces, pooled water, missing labels, open panels, and gauges nobody monitors because they are not wired to anything. A local gauge with no wire attached is only ever known by someone looking at it. The same goes for the valves and gauges that show whether a sprinkler system is ready between inspections.

Why it matters: in October 2023, during an upgrade at an Equinix data center in Singapore, a contractor closed valves on the chilled water system that should have stayed open. Cooling dropped, the halls heated up, and major banks in the country saw service outages. Whether a valve handle is open or closed is a visual fact. It is something you can see.

More sight sensors in the stack:

  • 3D depth cameras (stereo, time of flight and structured light) measure the distance to every point in view, so a moved cabinet or sagging cable tray becomes a measurement.
  • UV cameras make some oil films stand out, which helps reveal slow oil leaks on generators, transformers and pumps.

Thermal imaging and temperature: the sense of heat

What it measures: every object gives off infrared energy, and hotter objects give off more of it. A radiometric thermal camera captures that energy and stores an actual temperature value in every pixel, not just a color.

Stationary hubs can also use simpler heat sensors. Contact sensors measure by touch: an RTD is a wire whose resistance changes as it heats, and a thermocouple joins two metals that create a tiny voltage that changes with temperature. Spot infrared sensors read one point without touching it.

Why heat is such a good warning sign: electricity flowing through a loose or corroded connection meets extra resistance, a bit like water squeezing through a kinked hose. That resistance turns into heat. So a failing connection runs warmer than the healthy connections next to it, often long before anything trips. It is the same physics behind annual infrared inspections, and the reason teams ask whether continuous monitoring can replace infrared inspection.

What it catches: hot connections, overloaded breakers, cooling units that run but do not cool, and hot spots on racks.

Why it matters: in July 2022, during a record heatwave in London, several redundant cooling systems at a Google data center failed at the same time, and Google powered down part of a cloud zone to protect the hardware. In August 2023, a power sag at a Microsoft Azure site in Australia tripped chillers that did not restart on their own. Temperatures climbed and storage hardware had to be shut down. In both cases, rising temperature was the first physical sign.

Why the same angle matters: a thermal reading means the most when compared with the same spot last week, or with an identical part in the same frame. The robot returns to the same checkpoint, position and angle on every pass, and that repeatability means a change is a real change.

Vibration: the sense of touch for moving machines

What it measures: an accelerometer measures how quickly motion changes. A three axis accelerometer measures it in three directions at once: up and down, side to side, and front to back.

The useful part is the pattern. A healthy fan shakes in a steady, familiar rhythm. A worn bearing adds a new, faster rhythm on top. An unbalanced fan, a misaligned shaft and a loose mount each leave their own signature, so the pattern tells you which part is in trouble.

What it catches: wearing bearings in fans and pumps, chillers and computer room air conditioning units, plus imbalance, misalignment and looseness, while the machine is still running normally. A vibration history also shows when a repair did not hold, which is how teams break the cycle of recurring HVAC failures.

Why it matters: in November 2020, at a data center in Sydney, a faulty bearing in an air conditioning unit created friction, then heat, then smoke. The smoke set off the gas fire suppression system, and the force and noise of the discharge damaged disks belonging to the betting company Tabcorp. The company said it had received no warning of the mechanical failure beforehand. A mechanical problem became a fire alarm and then a storage problem, and shaking was the earliest signal in that chain.

Acoustic and ultrasonic sensing: the sense of hearing

What it measures:

  • Microphones capture audible sound, the basis of acoustic monitoring. Several working together as an array can tell which direction a sound comes from.
  • Ultrasonic sensors listen above human hearing. People hear up to about 20,000 vibrations per second; ultrasonic sensors listen up to around 100,000.
  • Acoustic cameras paint sound onto an image, and acoustic emission sensors pick up the tiny stress waves a material gives off as it cracks.

Why ultrasound is so useful for electrical gear: when electricity starts escaping where it should not, through damaged insulation, across a dirty surface or into the air, it crackles in the ultrasonic range. Engineers call these partial discharge, tracking and corona. Partial discharge is a series of tiny sparks inside insulation that slowly eat through it, and it is one of the early signs that insulation is failing.

That sound escapes through the seams and vents of closed cabinets, so ultrasonic screening can check electrical equipment without opening it. It is a big part of how a robot can inspect a data center without opening anything. Ultrasound also picks up the hiss of compressed air and gas leaks.

What audible sound catches: dry bearings, unbalanced fans, a pump losing its prime and relays that chatter. These are the changes people stop hearing because they walk past them every day.

Why it matters: in September 2016, a test of the gas fire suppression system at an ING Bank data center in Romania released a blast of sound loud enough to damage dozens of hard drives, and services were offline for about ten hours. Sound can be a hazard of its own, and a hub that measures it records what the equipment actually experienced.

One more hearing tool: ultrasonic thickness gauges time a sound pulse through a pipe wall to find thinning and corrosion in chilled water pipework.

Temperature, humidity, airflow and pressure: the sense of climate

What it measures:

  • Air temperature at a specific point, such as the front of a rack where servers pull air in.
  • Relative humidity: how much water the air is holding compared with the most it could hold at that temperature. Think of a sponge that is partly full.
  • Dew point: the temperature at which that water would turn into droplets. It is the same thing that makes a cold glass sweat on a summer day.
  • Airflow: how fast air is moving at a point.
  • Differential pressure: the difference in air pressure between two spaces, such as the two sides of a filter, or the space under a raised floor compared with the room above it.

What it catches:

  • Humidity that is too dry or too wet. Dry air raises the risk of static discharge, the tiny shock you get from a doorknob. Wet air leads to condensation and corrosion.
  • A reading at rack intake height shows what the equipment actually breathes, which can be very different from a wall sensor across the room.
  • As a filter clogs, the pressure difference across it climbs, a bit like breathing through a narrower and narrower straw.
  • Containment leaks and blocked airflow show up as changes in pressure and air speed, often around the cooling loads nobody owns.

Industry guidelines define recommended temperature and humidity ranges, and the hub records readings at the right height so they can be compared with each site's chosen range.

Why it matters: in November 2025, a cooling failure at a CyrusOne data center near Chicago halted CME Group's global futures and options trading for about ten hours. When cooling fails, room temperature is the first number that moves.

Particulate and air quality: the sense of a clean room

What it measures: a particulate sensor shines a small laser through a stream of air. Each particle that passes scatters a flash of light, and the sensor counts the flashes and sorts them by size. PM2.5 means particles smaller than 2.5 micrometers, about thirty times thinner than a human hair. PM1 and PM10 are smaller and larger size groups.

The stack can also measure carbon dioxide, by checking how much infrared light the gas absorbs.

What it catches: air contamination that damages hardware: dust that clogs filters and traps heat inside equipment, and conductive particles that can cause short circuits, such as zinc whiskers, tiny metal hairs that can grow from older zinc plated floor tiles and drift into servers. It also shows whether a room is slowly getting dirtier.

Why it matters: in February 2019, the local fire department said dust from construction work triggered the fire suppression system at a Wells Fargo data center in Minnesota. Systems were powered down, and ATM and online banking services were disrupted. Construction and fit out work is one of the most common sources of dust in a working facility.

VOC and gas sensing: the sense of smell

What it measures:

  • VOCs (volatile organic compounds) are carbon based vapors, including those from battery electrolyte. One sensor type uses a metal oxide surface whose resistance changes when gas touches it. Another, photoionization, uses ultraviolet light to knock electrons off gas molecules and measures the tiny current that creates.
  • Specific gases, each with its own sensor: hydrogen; carbon monoxide; corrosive gases such as hydrogen sulfide and sulfur dioxide, which slowly eat away at circuit boards; oxygen, which can drop after a gas suppression discharge; and refrigerants, including the newer, mildly flammable A2L refrigerants.
  • LEL, the lower explosive limit, is the smallest amount of a gas in air that can burn. Flammable gas sensors often report how close the air is to that limit.

What it catches: lithium cells under stress vent gas before they swell or run hot. Lead acid batteries give off hydrogen while charging, and hydrogen can burn once it reaches about four percent of the air, which is why fire codes require battery rooms to be ventilated well below that and why NFPA 855 matters for data center batteries. Leaking refrigerant both reduces cooling and, with A2L refrigerants, adds a flammability risk.

Sensor height matters too: hydrogen rises to the ceiling, while most refrigerants pool near the floor, so a hub is placed where the gas will actually be.

Why it matters: in October 2022, a fire that began in the lithium battery area of an SK C&C data center in South Korea disrupted Kakao's services for about 127.5 hours, and reports said the battery monitoring system had shown nothing abnormal beforehand. In September 2025, lithium UPS batteries caught fire during relocation work at South Korea's national government data center in Daejeon. Hundreds of government services went down, and reports said about 858 terabytes of data might be lost for good. Batteries can fail in ways their own monitoring does not show, which is why an independent nose in the room is a valuable second witness.

Liquid leak sensing: the sense of wet

What it measures: water conducts electricity. A leak sensor has two conductors close together, and when liquid touches both, a small current flows and the sensor knows it is wet. A point sensor watches one spot. A rope sensor detects liquid anywhere along its whole length, so it can run under a row of cooling units or along a pipe. Refrigerant and coolant sensors track the loss of those fluids as well.

What it catches: water and coolant leaks under raised floors, under cooling units and along liquid cooling lines. As liquid cooling brings water right up to the rack, leaks matter more than ever.

Why it matters: in April 2023, a water leak in the cooling system at a Google data center in Paris reached a battery room and led to a fire. Dozens of cloud services in the region were disrupted. Water and batteries are a dangerous pair, and the leak came before the fire.

Where it fits: a stationary hub with a rope sensor under a cooling unit or along a liquid cooling manifold watches continuously. On its route, the robot's camera spots pooled water as part of every camera inspection.

Smoke sensing: early context, never a replacement

What it measures: smoke particles in the air, detected by how they scatter or block a beam of light.

Its role: smoke sensing in the hub adds context. It does not replace the building's fire alarm, detection or suppression systems, the fire protection NFPA 75 expects for IT equipment, which remain in charge of life safety. What the hub adds is where the smoke was first seen, when, and what else changed around it, such as heat on a thermal image or gas near a battery string.

Why it matters: in March 2021, a fire at OVHcloud's campus in Strasbourg, France destroyed one data center building and took the site offline, affecting millions of websites. Fires in electrical and battery spaces can grow in minutes, so knowing where and how one started helps teams respond.

Process sensors: pressure, level, flow and motor health

These sensors measure what is happening inside pipes, tanks and motors.

  • Pressure sensors measure how hard a fluid pushes. Gauge pressure is compared with the room. Absolute pressure is compared with a perfect vacuum. Differential pressure is the gap between two points. They catch chilled water pressure loss, pump problems and low sprinkler system pressure, and they can replace or back up local pressure gauges that only a camera would otherwise read.
  • Level sensors measure how full a tank is. An 80 GHz radar level sensor sends a radio pulse down to the surface and times the echo, like shouting into a canyon. They track generator fuel and water tanks that keep emergency and standby power ready.
  • Flow sensors measure how much fluid moves through a pipe each second. Loss of chilled water flow was at the heart of both the Singapore and Australia cooling incidents above.
  • Oil quality, motor current and shaft runout sensors track wear particles in oil, the electrical pattern a motor draws, and how much a spinning shaft wobbles, all early signs of wear.

Why it matters: when Hurricane Sandy hit New York in 2012, flooding knocked out basement fuel pumps, and staff at one facility formed a bucket brigade, carrying diesel up the stairs by hand to keep the generators running. Fuel level and pump condition decide how long backup power lasts.

LiDAR and navigation: the sense of place

What it measures: LiDAR sends out laser pulses and times how long each one takes to bounce back. Millions of those distances build a 3D map of the room, made of points. The robot uses this to work out where it is while it maps, which engineers call SLAM, short for simultaneous localization and mapping.

Other platform sensors help the robot move safely:

  • An IMU, or inertial measurement unit, measures tilt and turning, so the robot knows how it is moving.
  • Proximity and time of flight sensors measure the distance to nearby objects, so the robot avoids obstacles in tight aisles.

Why it matters: a reading only means something if you know exactly where the sensor was pointed and that it was pointed at the right asset. LiDAR lets the robot return to the same checkpoint every time. It also builds a 3D digital twin that shows what changed from one map to the next: a moved rack, a new cable run, a blocked aisle, or a panel schedule that has drifted from what is installed. Industry surveys consistently find that human error and unmanaged changes sit behind a large share of outages, so seeing change is a safety tool in its own right.


How does the hub turn readings into evidence?

Short answer: by tying every reading to an asset, a position and a time, and by recording honestly when a reading could not be taken.

A number on its own is trivia. A number with context is evidence. "Breaker 14 in panel B was 112 degrees at 2:10 pm on Tuesday's run, measured from the same position as last week, when it was 96" tells a qualified person exactly what to look at.

The hub follows four rules to make that happen:

  1. Every reading is tied to a specific asset. Not "a warm spot in room 3," but the exact breaker, fan or battery string.
  2. Every reading is taken from the same checkpoint, position and angle on every pass, and that pose belongs in the inspection record, so changes over time are real changes.
  3. Every reading carries the run and the time it was taken, so the history builds itself.
  4. If a clean reading cannot be taken, the hub records that it could not. A blocked view or a closed door becomes a noted gap, never an invented number.

All of this feeds the same FacilityOps platform, alongside the building management system, DCIM tools and any fixed sensors a site already has.

One stop, every sense: a CRAH unit in a single capture

An illustrative stop at CRAH 4, with each sense and what it is compared against:

  • Thermal: the fan motor and its terminal box, compared with the twin unit on the NETA scale for similar components.
  • Visual: filter status light, drain pan, local gauges and the controller screen, photographed from the same pose as the last pass.
  • Acoustic and ultrasonic: airborne ultrasound in roughly the 20 to 100 kHz band picks up bearing wear, lubrication needs and leaks before anyone can hear them.
  • Vibration: fan and motor velocity against the commonly published ISO 10816 Part 3 zones, where 2.8 mm/s marks the edge of Zone B on a rigid foundation for this class of machine.
  • Temperature and humidity: supply air against ASHRAE's recommended 18 to 27°C.
  • Particulate: a count at the return, showing when filters load faster than the schedule assumes, against the ISO 14644 Class 8 target.
  • Gas: a refrigerant and VOC sniff at the coil and fittings.

Seven readings, one place, one time stamp. A warm motor alone is a maybe. A warm motor plus rising vibration plus a new ultrasonic signature at the same stop is a work order.

Coming next: a single condition score per stop that weighs all seven senses together, with each contributing reading one click away.

What the evidence says

  • A Pacific Northwest National Laboratory guide for the US Department of Energy puts predictive maintenance savings at 8 to 12 percent over a preventive only program, in its O&M Best Practices guide.
  • Boston Dynamics' Spot and Orbit 5.1 release combines an acoustic check, a thermal check and a short video of the same location into one inspection output, The Robot Report notes.

Why put a sensor hub on a robot or a drone?

Short answer: because a moving hub can cover the whole facility, read things that are not wired to anything, and measure every asset the same way every time.

A robot carrying a hub does the physical work of inspection. It drives the route, stops at each checkpoint, lines up its sensors, takes its readings and moves on, without skipping the far corner of the hall. That brings three advantages:

  • Coverage: one robot can carry a full set of senses past hundreds of assets on a single route, from the data hall to the electrical rooms.
  • Unwired assets: many important things in a data center are not connected to any monitoring system: local gauges, sight glasses, labels, doors, valve handles. A robot can go and look.
  • Consistency: the robot returns to the same position and angle on every pass, so this week's reading can be compared fairly with last week's.

Drones extend the same idea upward, to high and overhead places a ground robot cannot easily see.


Why would a sensor hub stay in one place?

Short answer: because some rooms are too small for a robot, and some spots deserve a watcher that never leaves.

Small and enclosed rooms. Many facilities have small electrical rooms, battery closets, UPS alcoves and compact plant rooms where there is barely room to turn around. A robot would be impractical there. A stationary hub fitted with only the sensors that room needs is the practical choice, and it is far more affordable than a robot for a space that size.

High risk and previously flagged spots. Some assets carry more risk than their neighbors: a busy switchboard, an older battery string, or a spot that has been flagged before for a higher chance of problems. A stationary hub placed there acts as a secondary, real time source of data. It keeps watching between robot passes and supplements what the robot finds.


How do stationary hubs and robots work together?

Short answer: the stationary hub is the tripwire, and the robot is the investigator.

Here is how that plays out, step by step:

  1. A stationary hub in a battery closet sees VOC levels start to climb above that room's normal baseline.
  2. The hub raises an alert, and the alert triggers a robot visit.
  3. The robot arrives with its full set of senses. It takes thermal images of the battery string, listens for unusual sound, reads the local gauges and indicator lights, and photographs the area.
  4. Now there are two independent sources on the same spot. If the robot's thermal image shows one cell running warmer than its neighbors, the case is far stronger than either reading alone. If the two sources disagree, that disagreement is itself a finding worth a closer look.
  5. A qualified person reviews the evidence and decides what happens next.

This is the difference between monitoring, inspection and robotic action working as one system. The hub fills the gaps between robot passes, and the robot brings the full investigation the moment it is needed.


What happens after a repair?

Short answer: a stationary hub watches the repaired spot for a set period to prove the fix held.

A repair is not finished just because a connection was tightened. The real question is whether the problem stays fixed. FacilityOps answers that with a post repair watch period:

  1. The robot finds the problem, for example a breaker connection running hotter than the identical breakers beside it.
  2. The reading before the repair becomes the baseline. It is the "before" picture.
  3. A qualified person makes the repair and sets how long the spot should be watched, for example two to four weeks.
  4. A stationary hub watches that exact spot continuously for the whole period, while the robot keeps running its normal route.
  5. The hub's readings are compared with the baseline. If the connection now runs at the same temperature as its neighbors, the fix is working.
  6. If the fix holds, the work order is closed with evidence showing before, after, and the steady readings in between.
  7. If the problem comes back, the hub raises an alert, the robot visits, and the issue goes back to a qualified person.

The result is a repair record that shows not just that work was done, but that it worked.


What does a sensor hub setup look like room by room?

Short answer: each room gets the sensors and the carrier that fit its size and its risks.

  • Small electrical room: a stationary hub with thermal, ultrasonic, temperature and humidity sensing.
  • Battery room: a stationary hub with VOC and gas, hydrogen, smoke and thermal sensing, plus regular robot visits.
  • Data hall: a robot carrying cameras and gauge reading, thermal imaging, temperature and humidity at rack intake height, airflow, differential pressure and particulate sensing.
  • Cooling plant: a robot carrying vibration, acoustic, thermal and gauge reading, with stationary hubs on flagged units watching vibration, refrigerant, pressure and leaks.
  • High and overhead areas: drone mounted cameras and thermal imaging.

Can the sensor hub be customized?

Short answer: yes. Customization is the whole point.

Plug and play. Add a new sensor to the hub and every machine carrying that hub has it on the next route, with no need to replace the robot.

Payloads differ by job. A typical data center payload centers on cameras and gauge reading, thermal imaging, climate sensing including airflow and differential pressure, leak detection for water, coolant and hydrogen, and vibration on cooling units and pumps. A battery closet hub looks completely different from a data hall robot. Beyond data centers, the same approach fits critical cooling plants, crypto mining facilities and industrial sites, each with its own mix of sensors.

Hardware agnostic. Because the intelligence lives in the hub and the platform, the same senses can ride on different robot platforms, on drones or on fixed mounts, and every reading lands in one record.


Does a sensor hub replace a BMS, DCIM or fixed sensors?

Short answer: no. It works alongside them.

A building management system, DCIM tools and fixed sensors are excellent at what they are wired to watch, and they keep doing that job. The hub adds the physical layer around them: the unwired gauge, the warm connection, the bearing starting to shake, the propped door. Hub readings sit in the same record, so a team sees one picture. It is the same reason continuous monitoring does not stand in for a physical infrared inspection.


Which standards does sensor hub evidence support?

Short answer: hub evidence supports the inspection and documentation work behind nine compliance surfaces covered by one route:


How it all works together

Every sensor in the hub measures one thing. Cameras see. Thermal imaging feels heat. Accelerometers feel shaking. Microphones and ultrasonic sensors hear. Gas and VOC sensors smell. Leak sensors feel wet. LiDAR knows where everything is.

Together, they catch problems earlier, confirm each other, and turn readings into evidence a qualified person can act on.

The carriers work together the same way. Robots cover the whole facility. Drones reach up high. Stationary hubs watch the small rooms and the spots that need extra care. A hub alert sends the robot to investigate, and after a repair, a hub watches to prove the fix held.

And none of it is one size fits all. Every hub is built for its room, its risks and its site, from a single battery closet to an entire campus. Everything feeds one platform and one record.

For how hub readings become audit ready evidence without extra paperwork, see how to automate inspection evidence for a data center.


If you want to see what the record looks like today, we can send you a sample inspection record.


Frequently Asked Questions

What is a sensor hub in a data center?

A sensor hub is a single plug and play module that holds many sensors, such as thermal, vibration, ultrasonic, gas, humidity and leak sensors. It can ride on a robot or drone or be fixed in place, and it ties every reading to a specific asset, position and time before sending it to one platform.

What sensors does the FacilityOps sensor hub include?

The core data center payload covers cameras and gauge reading, thermal imaging, vibration, acoustic and ultrasonic sensing, temperature and humidity, particulate, VOC and gas, and smoke sensing. The stack also includes airflow, differential pressure, liquid leak, hydrogen, refrigerant, process and 3D sensors, fitted to each site as needed.

Why use a stationary sensor hub instead of a robot?

A stationary hub suits small rooms such as battery closets and small electrical rooms, where a robot is impractical and a hub is more affordable. It also suits high risk or previously flagged spots, where it gives continuous, real time readings between robot passes.

Can a sensor hub alert trigger a robot inspection?

Yes. When a stationary hub sees a reading move away from its baseline, it can trigger a robot visit. The robot then brings its full set of sensors to investigate, giving a qualified person two independent sources of evidence on the same spot.

What is a post repair watch period?

After a repair, a stationary hub watches the repaired spot continuously for a period set by a qualified person, often two to four weeks. Its readings are compared with the pre repair baseline. If the fix holds, the work order is closed with evidence. If the problem returns, an alert triggers a robot visit.

Does a sensor hub replace the fire alarm or BMS?

No. Smoke sensing in the hub adds context, but life safety systems stay in charge. The hub works alongside the building management system, DCIM and fixed sensors, adding physical readings those systems are not wired to collect.

Can the sensor hub be customized for my facility?

Yes. The hub is plug and play and fully customizable, so each room gets only the sensors its risks call for. Adding a sensor to the hub gives it to every machine that carries that hub on its next route.

What can ultrasound detect in electrical and mechanical equipment?

Airborne ultrasound instruments listen in roughly the 20 to 100 kHz band and shift those sounds down so a person can hear them. That reveals electrical arcing, tracking and corona, bearing wear and lubrication needs, and pressure, vacuum, valve and steam trap leaks. The FacilityOps sensor hub records ultrasound at the same spot on every pass, so a new signature stands out.

How much does predictive maintenance save compared with preventive maintenance?

About 8 to 12 percent, according to a Pacific Northwest National Laboratory guide for the US Department of Energy, and independent surveys it cites report 70 to 75 percent fewer breakdowns and 35 to 45 percent less downtime. Those savings depend on spotting condition changes early. The FacilityOps sensor hub supplies the condition data that predictive maintenance runs on.



Everything in this piece, as a checklist you can take on your rounds

Turn the key points from this article into a practical inspection checklist.