Data Center Inspection, Run by an Autonomous Fleet
Inspection robots and sensor hubs check every room, every round, and record what they find.
- 10 room types
- 1 route
- Every round recorded
Robots and Sensor Hubs, Working as One

Inspection Robot
Walks one route and checks the same points, every round.
Sensor Hub
Plug and play sensors that ride on the robot or mount in tight, high risk spots.
One Inspection Record
Every finding is time stamped, mapped to a 3D digital twin and turned into a work order.
Every Room We Inspect
One robot route covers the facility. Fixed hubs cover the rest.
Server Rooms and Data Halls
Racks, inlet temperatures, airflow, containment
Electrical and Switchgear Rooms
Hot spots, enclosure condition, working clearances
Mechanical and Cooling Rooms
Coils, filters, pumps, piping, condensate
UPS and Battery Rooms
Battery temperature, labels, spacing
Generator, ATS and Fuel
Connections, fuel leaks, controller status
Busway, PDU and RPP
Joints, taps, branch connections
Substation and Transformers
Hot spots, leaks, corrosion, nameplates
Fire, Egress and Safety
Valve positions, gauges, exits, blocked paths
Liquid Cooled Halls
Manifolds, quick disconnects, CDU skids, signs of leaks
Small and Enclosed Rooms
Watched around the clock by a fixed hub
Autonomous Inspection in Action
The robot patrols the data hall, capturing equipment condition, gauges and visual evidence.
The robot captures visual and thermal conditions in electrical rooms and maps findings to assets.
At the CRSC Data Center, powered by Solutions IS, the robot caught a failed condenser 4.5 hours before the facility's sensors alarmed.
Read the case study →Less Downtime
Problems caught before they take equipment down.
Lower Cooling Cost
Rack level temperature records show when set points can safely go up.
Audit and Insurer Ready
Every round is proof the inspection happened.
Technicians on Skilled Work
The robot takes the rounds. Your team fixes what it finds.
Built Around Data Center Industry Guidance
Inspection rounds built around the practices data centers already follow.
NFPA 70B
Supports electrical preventive maintenance programs.
Uptime Institute
Supports inspection practices behind uptime and resilience.
ANSI / NETA
Guides inspection of switchgear, UPS and power distribution.
DOE / ENERGY STAR
Encourages efficient cooling and energy use.
Get the Capability Brief
Three fields. We’ll send the capability brief straight away.
Improve Inspection Consistency Across Your Data Center
See how FacilityOps AI helps standardize inspections, improve operational visibility, and create audit-ready inspection records.