Safety · OSHA 29 CFR Part 1910

OSHA 1910 for Data Centers: What the Safety Standards Require, and the Rounds Nobody Walks

Updated · FacilityOps researchers and writers

OSHA 1910 is the set of general industry safety standards issued by the Occupational Safety and Health Administration, published as Title 29 of the Code of Federal Regulations, Part 1910. A data center is general industry, so OSHA 1910 applies to its working spaces.

In a data center, most of what it asks for is physical and visible: clear walkways and exit routes, clear working space in front of electrical equipment, fire extinguishers in place and checked, and signs people can see.

Almost all of it changes week to week. Every round a person did not walk is a stretch of time in which that state went unrecorded.

Key takeaways

  • OSHA 1910 is the Occupational Safety and Health Administration's general industry standard, 29 CFR Part 1910, and it covers data center working spaces.
  • Several parts write inspection into the rule: walking and working surfaces inspected regularly and as necessary, and portable fire extinguishers visually inspected every month.
  • In 2026, a serious violation can cost up to $16,550 and a willful or repeated one up to $165,514, per violation.
  • Most findings are ordinary conditions that come and go between rounds. A dated record from the same points on every pass shows how the spaces actually were.

What is OSHA 1910?

OSHA, the Occupational Safety and Health Administration, is the agency of the U.S. Department of Labor created by the Occupational Safety and Health Act of 1970. Its general industry standards are published as 29 CFR Part 1910, titled Occupational Safety and Health Standards.

Part 1910 covers most workplaces that are not construction, maritime or agriculture, and a data center is one of them. Construction work on site, such as a fit out or a new hall, falls under Part 1926 instead.

Federal OSHA enforces the standards directly in most states. There are 29 OSHA approved State Plans, 22 of which cover private sector workers, and each must be at least as effective as federal OSHA.


Which parts of OSHA 1910 apply in a data center?

Part 1910 is organized into subparts. These are the ones a data center meets every day:

  • Walking and working surfaces, Subpart D: floors, aisles and walkways kept clean, dry where practical and free of hazards (1910.22)
  • Exit routes, Subpart E: routes kept free and unobstructed, with exits marked and lit (1910.37)
  • Fire protection, Subpart L: portable fire extinguishers mounted, accessible and inspected (1910.157)
  • Electrical, Subpart S: clear working space in front of electrical equipment and disconnects marked with their purpose (1910.303), plus safe work practices (1910.331 to 1910.335)
  • Hazard signs and lockout, Subpart J: safety signs (1910.145) and control of hazardous energy during service (1910.147)
  • Materials handling and storage, Subpart N: aisles and passageways kept clear where materials are moved and stored (1910.176)

The standards set the duty. A qualified person and, where an inspection happens, OSHA or the State Plan decide whether a workplace meets them.


What does OSHA 1910 say about inspections?

Several standards write the inspection into the rule itself, and the requirement is ongoing rather than once a year.

  • Walking and working surfaces must be inspected regularly and as necessary, and a hazard must be corrected or guarded before anyone uses the surface again (1910.22(d)).
  • Portable fire extinguishers must be visually inspected every month, with an annual maintenance check whose date is recorded (1910.157(e)).
  • Exit routes must stay free and unobstructed, with nothing placed in them even temporarily, and nothing may block the view of an exit sign (1910.37).
  • Working space in front of electrical equipment must be provided and maintained, at least 30 inches wide, and may not be used for storage (1910.303(g)).

Every one of these is a physical condition someone can see. The question an inspector asks is whether it was true between the rounds, not only on the day of the visit.


What do OSHA violations cost in 2026?

OSHA publishes its maximum civil penalties each year. For 2026 there was no inflation increase, so the amounts match 2025:

  • Serious and other than serious violations: up to $16,550 per violation
  • Willful and repeated violations: up to $165,514 per violation
  • Failure to abate: up to $16,550 for each day past the abatement date

The bigger cost is usually the incident behind the citation: a trip in a cluttered aisle, a blocked exit, or a technician working in a space that was supposed to be clear.

Where do citations and electrical deaths actually land?

In OSHA's final fiscal year 2025 data, hazard communication ranked second with 3,010 violations, and lockout/tagout fourth with 2,562 (Safety+Health, 2026). OSHA's preliminary 2026 list moves lockout/tagout up to third (OSHA).

The Bureau of Labor Statistics counted 130 workplace deaths from exposure to electricity in 2024, down from 142 in 2023 (BLS, 2026).

Most victims are not electricians. Of 1,940 electrical workplace deaths from 2011 to 2023, 74 percent were workers outside electrical occupations, including 43 HVAC and refrigeration mechanics (ESFI, 2025).

Data processing and hosting is a partially exempt industry, so it does not keep routine OSHA injury logs unless asked in writing (OSHA). That makes your own inspection record the main evidence of how a space is kept.

The reporting duty still applies. A work death must be reported within 8 hours, and a hospitalization, amputation or loss of an eye within 24 hours (OSHA 1904.39).


Why is the safety record thinner than the safety program?

The safety program exists. The training happens. The walks are scheduled. All of that is real work.

What rarely exists is a dated record of what the spaces actually looked like between those walks. The program says how the spaces should be kept. The record would show how they were.

A round gets skipped because a chiller went down that morning, or two people were on leave. That is ordinary operations, not negligence, and nothing captures it either way.


What does the gap look like in a data center?

  1. 1. A pallet parked in front of an electrical panel for two weeks after a delivery.
  2. 2. A walkway narrowed by cable reels during a fit out.
  3. 3. Boxes stored in the working space of a switchboard that was clear at commissioning.
  4. 4. An exit sign covered by a new cable tray, or an exit door propped open.
  5. 5. A fire extinguisher moved, blocked or missing from its mount.
  6. 6. A spill or a leak on a raised floor tile that nobody reported.

None of these is dramatic. All of them are the kind of thing someone asks about later, and most of them come and go between two rounds without leaving a trace.


The 10 minute OSHA safety walk

All you need is a phone and the route an OSHA compliance officer would take: in through the electrical room door, along the exit route, and up to each panel. Photograph each space from the same spot every time.

  1. 1. Walkways and aisles: clear, dry, no trip hazards, no damaged floor tiles
  2. 2. Exit routes: unobstructed along their full length, doors closing and unlocked from inside
  3. 3. Exit signs: lit, visible from the route, not covered
  4. 4. Electrical working space: nothing stored in front of panels, switchboards or disconnects
  5. 5. Fire extinguishers: on their mounts, unblocked, gauge in the operable range, tag current
  6. 6. Signs and labels: present, readable, not covered
  7. 7. Storage: nothing new parked in aisles, plant rooms or electrical rooms
  8. 8. The record: date, time, a photo of each space and anything that changed

Anything out of place goes to the person who owns that space. Done every week, this turns a safety program into a record of how the spaces actually were.


How FacilityOps keeps every working space on record

A FacilityOps robot turns the safety walk into a repeatable, machine run inspection. It runs a fixed route through data halls, electrical rooms, plant rooms and corridors on a schedule, including the weeks the round would have been skipped.

What the robot does at every checkpoint

  1. 1. Navigates to the checkpoint using 3D lidar and simultaneous localization and mapping (SLAM), and confirms the space or asset in front of it is the one the route names.
  2. 2. Stops on the same mark in front of each panel and exit door on every pass, and stores that pose with the capture, so this month's working space measurement lines up with last month's.
  3. 3. Images the space with a pan tilt zoom camera: exit signs and whether they are lit, doors, labels, and every fire extinguisher on the route. The camera reads the extinguisher gauge, so a needle out of the operable range is recorded with the image.
  4. 4. Measures the space. Every pass updates a 3D digital twin, so a narrowed walkway, a blocked exit route or boxes in the working space in front of a panel shows up as a measured change, not a judgment call.
  5. 5. Senses what a photo misses: thermal capture of the panels it passes, temperature and humidity in the space, and the FacilityOps sensor hub's air quality and gas readings.
  6. 6. Marks a space it could not see, such as a locked electrical room or a door shut across the route, as not inspected, so the record never shows a clear space that nobody looked at.

What happens when something changes

  • The FacilityOps platform compares every capture with the same checkpoint's last pass, so a condition that appeared since the last round stands out.
  • Storage in a working space or an exit route goes to whoever owns that room, usually the facilities supervisor, with last pass's photo next to this one. It opens a work order in FacilityOps or in the work order system you already run.
  • The next pass confirms the space is clear again, so the record shows the fix as well as the finding.

An illustrative record entry

Electrical room 2, switchboard SB 1 · Run 63, checkpoint 18 · Captured from the same pose as run 62

Change found: two pallets inside the working space in front of SB 1, leaving 19 inches of the 30 inch minimum width clear. Not present on run 62.

Routed to: facilities supervisor, work order opened. Closed: run 64 shows the working space clear.

Fixed route rounds like this already run in production. Since July 28, 2026, a FacilityOps robot has inspected the CRSC Data Center, powered by Solutions IS, in Houston, on a set route, logging more than 1,600 observations across its first 19 autonomous runs.

A monthly scorecard: one electrical room and its exit route

Four weekly robot passes, each line scored against its OSHA rule. The rules come from 29 CFR 1910; the results are illustrative.

  • Working space depth at switchboard SB 1, 480 volts, grounded parts opposite: at least 3.5 feet clear under 1910.303(g)(1). Weeks 1 to 4: pass, pass, fail, pass.
  • Working space width: 30 inches or the width of the equipment, whichever is greater. Pass all four weeks.
  • Headroom: 6.5 feet for installations built on or after August 13, 2007. Pass all four weeks.
  • Nothing stored in the working space: week 3 fail, two pallets in front of SB 1, gone on the next pass.
  • Exit route free and unobstructed under 1910.37(a)(3): week 2 fail, a cart parked across half the corridor.
  • Exit sign: the word Exit at least 6 inches high and lit to at least 5 foot candles. Pass, with a light reading logged each week.
  • Extinguisher at the room door: on its mount, unblocked, gauge in the operable range, which is the monthly visual check under 1910.157(e)(2). Pass.
  • Circuit markings at each disconnect: legible and durable under 1910.303(f)(2). Week 4 fail, one faded label.

Month total: 28 of 32 checks passed, four exceptions opened and every one closed with a photo. That single page answers most of what an inspector or an insurer's risk engineer will ask about this room.

Coming next: reading the punch on each extinguisher's maintenance tag, so a missed annual service shows up on the monthly scorecard instead of at the next inspection.

What the evidence says

  • OSHA sets minimum working space depth for equipment up to 600 volts at 3 feet for 0 to 150 volts to ground, and at 3, 3.5 or 4 feet for 151 to 600 volts, depending on what sits opposite the equipment, per 29 CFR 1910.303(g)(1).
  • Headroom in front of that equipment is 6.5 feet for installations built on or after August 13, 2007, and required working space may not be used for storage, OSHA states.
  • Exit signs must spell Exit in letters at least 6 inches high and be lit to at least 5 foot candles, under 1910.37(b).
  • Every portable extinguisher gets a monthly visual check and an annual maintenance check, and the maintenance record is kept one year after the last entry or for the life of the shell, whichever is less, under 1910.157(e).

The same space, from the same spot, on every pass, including the busy weeks. That is the difference between saying the spaces are kept clear and showing that they were.

The robot does not run your safety program, train anyone or make anyone safe. It records conditions, and people do the rest.


How FacilityOps supports OSHA 1910, requirement by requirement

FacilityOps carries the inspection and documentation load, so the safety team spends its time fixing conditions instead of finding them.

  • Walking and working surfaces (1910.22): surfaces on the route are captured on every pass, so the inspection happens regularly by design and a hazard is dated the day it appears.
  • Exit routes (1910.37): the digital twin shows anything placed in an exit route, and the camera records whether exit signs are lit and visible.
  • Fire extinguishers (1910.157): every extinguisher on the route is photographed in place with its gauge read, giving the monthly visual inspection a dated record. The inspection sign off stays with the site's designated person.
  • Electrical working space (1910.303): storage in front of panels and switchboards is measured, not guessed, and disconnect labels are photographed on every pass.
  • Signs (1910.145): missing, covered or faded safety signs are recorded with a date and an image.
  • Proof for inspectors and insurers: every capture is tied to its run, checkpoint and time, so the record shows the spaces between visits, not only on the day.

The same route covers the panels under the NEC, the battery room under NFPA 855 and the data hall under NFPA 75, so the safety record is part of one facility record across all nine compliance surfaces.

FacilityOps documents conditions. It does not run safety programs or determine compliance: that stays with qualified people, OSHA and the State Plans.


Five questions to ask about your safety record

A compliance officer can ask any of these on the day of a visit. Answer them from a dated record and the walk goes quickly.

  1. 1. When was each electrical room last walked, and can you show what it looked like?
  2. 2. Was anything stored in an exit route or a panel's working space in the last month?
  3. 3. Can you show the monthly check of every fire extinguisher, with the date?
  4. 4. Which rounds were skipped in the last quarter, and what happened in those spaces?
  5. 5. For every hazard found last quarter, where is the proof it was fixed?

OSHA 1910 questions we hear most

What does OSHA 1910 stand for?

OSHA is the Occupational Safety and Health Administration. 1910 refers to Title 29 of the Code of Federal Regulations, Part 1910, the Occupational Safety and Health Standards for general industry.

Does OSHA 1910 apply to data centers?

Yes. A data center is general industry, so Part 1910 covers its working spaces. Construction work on site falls under Part 1926, and states with OSHA approved State Plans enforce standards at least as effective as the federal ones.

How often does OSHA require workplace safety inspections?

It depends on the standard. Walking and working surfaces must be inspected regularly and as necessary, and portable fire extinguishers must be visually inspected every month with an annual maintenance check.

What are the OSHA penalties in 2026?

Up to $16,550 per serious or other than serious violation, up to $165,514 per willful or repeated violation, and up to $16,550 per day for failure to abate. There was no inflation increase for 2026.

What does OSHA require in front of electrical panels?

Clear working space must be provided and maintained in front of electrical equipment, at least 30 inches wide or the width of the equipment, and it may not be used for storage (1910.303(g)).

Can exit routes be blocked temporarily?

No. OSHA 1910.37 requires exit routes to be kept free and unobstructed, with no materials or equipment placed in them, even temporarily.

What should a safety inspection record include?

The date, the route, a photo of each space from the same spot, what was found, who it went to, and proof it was fixed. A condition that appears and clears between rounds only shows up if the record is regular.

Can a robot do OSHA safety inspections?

A robot can capture the condition of walkways, exit routes, working spaces, signs and fire extinguishers from the same points on every pass, and send anything out of place to the person who owns it. The safety program and compliance decisions stay with people.

How does FacilityOps help with OSHA 1910?

A FacilityOps robot walks a fixed route on a schedule, measures and photographs every working space from the same position, flags changes since the last pass, and turns each one into a work order. The record shows how the spaces were between visits.

How long must fire extinguisher inspection records be kept under OSHA?

OSHA requires the annual maintenance record to be kept for one year after the last entry or for the life of the shell, whichever is less. Every portable extinguisher also needs a visual check each month and a maintenance check each year. A FacilityOps robot round photographs each extinguisher on its route with a date stamp, so the monthly visual check leaves a record you can show.

How big do exit sign letters have to be under OSHA?

OSHA requires the word Exit in plainly legible letters at least 6 inches high, with main strokes at least three quarters of an inch wide. Signs must be lit to at least 5 foot candles, and doors that could be mistaken for exits must be marked Not an Exit. A FacilityOps robot round captures dated photos and light readings at each sign along the exit route.

Does OSHA require circuit breakers and disconnects to be labeled?

Yes. OSHA requires each service, feeder and branch circuit to be legibly marked at its disconnecting means or overcurrent device to show its purpose, and the marking must be durable enough for the environment. Motor disconnects need the same marking unless their purpose is obvious. A FacilityOps robot round photographs panel directories and disconnect labels on a schedule, so faded or missing markings show up in the dated record.


If you want to see how the state of a working space is recorded week to week, we can send you a sample inspection record.

Want this scorecard for your own electrical rooms? Book a call and we will scope a one month trial on your working spaces and exit routes, with the pass criteria written down before the first round.


Everything in this piece, as a checklist you can take on your rounds

Turn the key points from this article into a practical inspection checklist.